Version 1 (modified by 11 years ago) ( diff ) | ,
---|
Updating to Reggie 2.15
The following items should be performed after updating to Reggie 2.15.
NOTE! The procedures in this document are preliminary and may change before the final release!
1. Remove incorrectly registered SequencingRun
items
All SequencingRun
items registered with Reggie 2.14 are incorrectly registered. The easiest way to fix this is to remove all existing
SequencingRun
and use Reggie 2.15 to redo the registration. The following steps should work:
- Go to View->Derived bioassays.
- Make an export of all columns in case comments, annotations and other information is needed when re-registering.
- Select all
SequencingRun
items. - Use Set owner to take ownership of all selected items (to make it easier to delete them from the trashcan).
- Click Delete. This should put all selected
SequencingRun
items in the traschcan. - Go to View->Trashcan and finalize the deletion.
2. Redo the sequencing startup registration
The delete information about SequencingRun
items need to be re-registered using the Register sequencing started wizard.
The wizard should be completed once for each flow cell (no pair-wise registration).
- Go to Extensions->Reggie and start the Register sequencing started wizard.
- Operator and Comments can be copied from the information that was exported in step 1.2 above.
- All other information is retreived from the
runParameters.xml
file that is created by the HiSeq for each sequencing run. - Finish the wizard and repeat for each flow cell.
The Register sequencing ended and Confirm sequencing completed wizards can then be used to finalize the registration for each of the sequencing runs.