Opened 13 years ago

Last modified 13 years ago

#344 closed defect

Exception when trying to register more than one specimen tube for a case — at Version 2

Reported by: Nicklas Nordborg Owned by: Nicklas Nordborg
Priority: major Milestone: Reggie v2.0.2
Component: net.sf.basedb.reggie Keywords:
Cc:

Description (last modified by Nicklas Nordborg)

  1. Start the specimen tube registration wizard and enter a case name.
  2. In the second step set "Number of tubes" to 2 (or higher). The rest of the information can be left empty or filled in. It doesn't seem to matter.
  3. In the third step, boxes should already be filled in. Use the 'Suggest' links to automatically get row and column coordinates or enter them manually.
  4. As soon as coordinates for at least two specimen tubes have been entered (or suggested) the form is disabled and an error message is displayed:
For input string: "null"

Currently there seems to be no workaround and it is not possible to register cases with more than one specimen tube.

It seems to be working if tabbing through all input fields in the order they appear. The critical part seems to be that if each of the "Box" fields have been in focus the wizard works, but if at least one of the "Box" fields is skipped it will generate the above error as soon as a "Column" field loses focus or if the "Create" button is clicked.

Change History (2)

comment:1 by Nicklas Nordborg, 13 years ago

Milestone: Reggie v2.0.2
Status: newassigned

comment:2 by Nicklas Nordborg, 13 years ago

Description: modified (diff)
Priority: blockermajor